2WA/2NJ/2RK-1
6-95
Setting: Type
1.Change the setting value by using [+] [-] key or the numeric keypad.
* :(High altitude grain mode) Perform AC calibration at installing in a high altitude and improve
that image density becomes lighter.
The following are automatically changed if "+1" is set up in the Type.
If current setting is [Normal2] or [Normal3], change to [Normal1].
The U161 [GRAIN MODE] is set to [Mode2]
2.Select [Execute].
3.Press the [Start] key to set the setting value.
Setting: Magnification
1.Select the item to set.
2.Change the setting value by using [+] [-] key or the numeric keypad.
3.Press the [Start] key and fix the setting value.
Setting: Image Preference
1.Select the item to set.
2.Change the setting value by using [+] [-] key or the numeric keypad.
3.Press the [Start] key to set the setting value.
* :If the set value is reduced, toner consumption decreases.
4.Turn the power switch off then on. Wait more than 5 seconds between the power off and on.
Setting: Lead Density
1.Select the item to set.
* :Initial setting: 0(Off)
2.Press the [Start] key and then fix the setting value.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
Items Contents
0 Continue the present setting and execute AC calibration
+1 Set high altitude grain mode On and execute AC calibration
+2 Cancel high altitude grain mode setting and execute AC calibration
Items Contents Setting range Data
variation
Initial
setting
K Set it at the time of Black developing leak
outbreak
-10 to 15 - 10
Items Contents Setting range Data
variation
Initial
setting
Copy Sets the copy toner density -1 to 1 - 0
Items Contents
On Set
Off No set