2WA/2NJ/2RK
6-101
Contents
Displays the developer drive time to be a Refer ence for the toner density control correction.
Purpose
Execute to check the developer drive time since replacing the developer unit.
Method
1.Press the [Start] key.
* :Displays the developer drive time.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
Contents
Displays the developer counter
Purpose
Execute to check the developer unit usage status.
Method
1.Press the [Start] key.
* :The developer count is displayed.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
U157 Developer drive time
(Message: Developing Unit Drive Time)
Items Contents
K Displays the Black developer unit drive time.
U158 Developer counter
(Message: Developing Unit Counter)
Items Contents
K Displays the black developer counter.