2WA/2NJ/2RK
6-104
Setting: Low Power Mode
1.Select the mode to set.
* :Initial setting: Mode0
2.Press the [Start] key to set the setting value.
Setting: Belt Mode
1.Select the mode to set.
* :Initial setting: 1(On)
2.Press the [Start] key to set the setting value.
Setting: Ready Time Adjust
1.Change the setting value by using [+] [-] key or the numeric keypad.
2.Press the [Start] key to set the setting value.
*: If the alpha value lowers, the aging activated temperature executing after the steady at a quiet mode
becomes lower.
*: Lowering the alpha value could deteriorate the fuser performance due to aging would not be activated
during quiet mode.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
Items Contents
Mode0 Present state control mode (Usually not used)
Mode1 Fuser temperature step-down mode
Mode2 Productivity reduction mode
Items Contents
On If the lower power mode transition time is 2 minutes or more, it enters
into the press heater control mode (low power mode)
Off IH control until the low power mode transition time
Items Contents Setting range Data
variation
Initial
setting
Value Activating temperature correction value
low-temperature Aging: (α)
0 to 5 1 2.0
Temperature to
aging activation
Less than 13+α°C 13+α°C or more 18°C or more
Aging time 60 seconds 35 seconds 0 sec