2WA/2NJ/2RK-2
6-103
Initial setting
Setting: Print
1.Select the item to set.
2.Change the setting value by using [+] [-] key or the numeric keypad.
3.Press the [Start] key to set the setting value.
Initial setting
Items 90ppm 80ppm 70ppm
100V 120V 220-
240V
100V 120V 220-
240V
100V 120V 220-
240V
Ready(Center) - 145 145 135 145 145 130 135 135
Ready(Edge) - 100 100 90 100 100 90 100 100
Ready(Press) - 4040 404040 404040
Drive(Center) - 160 160 150 160 160 145 150 150
Wait(Center) - 160 160 150 160 160 145 150 150
Low Power
(Center)
- 100 100 100 100 100 100 100 100
Full Speed
Shift(Center)
- 5050 505050 505050
Pressure
(Center)
- 150 150 150 150 150 145 145 145
Items Contents Setting
range
Full Speed
Print(Center)
Temperature at maximum print speed
(Center)
130 to 200
Duplex
Shift(Center)
Shift temperature at full speed duplex print
(Center)
-20 to 20
Items 90ppm 80ppm 70ppm
100V 120V 220-
240V
100V 120V 220-
240V
100V 120V 220-
240V
Full Speed
Print(Center)
- 160 160 150 160 160 145 150 150
Duplex
Shift(Center)
-00 000 000