Displays/clears the fuser counter and fuser correction counter.
Purpose
Execute to check the fuser counter. Also, execute to clear the fuser correction counter after
replacing the fuser discharger needle unit.
Method
1.Press the [Start] key.
* : The fuser count is displayed.
Setting: Correction
1.Select [Correction].
2.Change the setting value by using the [+] [-] keys or the numeric keys.
3.Press the [Start] key and confirm the setting value.
Method: Clear
1.Select [Clear].
2.Press the [Start] key.
* :The fuser correction counter is cleared.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
U167 Clearing the fuser count
(Message: Clear Fuser Counter)
Items Contents
Cnt Displays the fuser count
Release(Time) Displays the fuser unit drive time (release)
Press(Time) Displays the fuser unit drive time (press)
Correction Displays/ changes the fuser correction counter
Clear Clears the fuser correction counter