2WA/2NJ/2RK
6-108
Contents
Change the fuser drive control setting
Purpose
Set the fuser drive control after completing the print as the fuser trace measure.
Setting
1.Press the [Start] key.
2.Select the [Bias].
3.Change the setting value by using [+] [-] key or the numeric keypad.
4.Press the [Start] key and then fix the setting.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
Contents
Change the fuser phase control.
Purpose
Use the fuser phase control change.
Setting
1.Press the [Start] key.
2.Change the setting value by using [+] [-] key or the numeric keypad.
3.Press the [Start] key and then fix the setting.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
U193 Fuser drive control setting
(Message: Set Fuser Drive Control)
Items Contents Setting range Initial setting
B/W Monochrome (High speed) 0 to 200 50
Half Half speed 0 to 200 50
U198 Fuser phase control setting
(Message: Set Fuser Phase Control)
Items Contents Setting range Initial setting
Mode Fuser phase control type setting 0 to 1 0