2WA/2NJ/2RK
6-223
Contents
Sets the time-out time for the fax communication.
Purpose
Mainly, executed to improve the accuracy of communication for international communication
Method
1.Press the [Start] key.
2.Select the item to set.
Setting: T0 Time Out
Sets the time before detecting a CED or DIS signal after a dialing signal is sent.
Sets to prevent disconnection of a line that occurs depending on the quality of the exchange, or
when the destination unit sets the auto switching function.
1.By using the [+] [-] keys or the numeric keys, change the setting value.
2.Press the [Start] key to set the setting value.
* :[Completed] is displayed.
Setting: T1 Time Out
Sets the time before receiving the correct signal after call reception.
*This setting is usually unnecessary.
1.By using the [+] [-] keys or the numeric keys, change the setting value.
2.Press the [Start] key to set the setting value.
* :[Completed] is displayed.
Setting: T2 Time Out
U641 Communication time setting 2
(Message: Communication Time 2)
Items Contents
T0 TIME OUT Sets the T0 time-out time.
T1 TIME OUT Sets the T1 time-out time.
T2 TIME OUT Sets the T2 time-out time.
Ta TIME OUT Sets the Ta time-out time.
Tb1 TIME OUT Sets the Tb1 time-out time.
Tb2 TIME OUT Sets the Tb2 time-out time.
Tc TIME OUT Sets the Tc time-out time.
Td TIME OUT Sets the Td time-out time.
Contents Setting
range
Initial
setting
Sets the T0 time-out time. 30 to 90 s 56
58 (100 V model)
Contents Setting
range
Initial
setting
Sets the T1 time-out time. 30 to 90 s 36
38 (100 V model)