Print room conditions
Minimal area
Configuration Dimensions
printer (W x D x
H)
Minimal floor
area
Minimal room
height
Minimal volume
Standard 880 cm x 275 cm
x 240 cm /
29 x 9.2 x 7.1 ft
1,040 cm x 575
cm /
34.2 x 18.1 ft
300 cm / 118"
205 m
3
/
12,509,867 in
3
Maximal floor load
Configuration Weight Surface load Floor evenness
Standard 400 kg / 881 lb
400 kg/m
2
12 N/mm
2
Class 5 floor
(NEN2747)
Environmental conditions
Condition
Temperature*
20
o
C - 26
o
C / 68
o
F - 78.8
o
F
Relative humidity* 30% - 50%
Air pressure 840 - 1060 mbar
Compressed air 8 bar; 500 liters/min
Power consumption Maximum 38 Kw
For (80 g/m² / 20 lb bond) media: 16 Kw
Power requirements Europe 230 V; 3 phases star; 80 A; 100 A per phase
Device fuse: 3 x 100 A
Power requirements USA 208 V; 3 phases delta; 160 A per phase
or
240 V; 3 phases delta; 140 A per phase
or
277 V; 3 phases star; 65 A per phase
Device fuse: 3 x 191 A, 3 x 175 A, 3 x 82 A
*Do not allow conditions in the print room to change suddenly. Keep doors to adjacent rooms
closed. Use accurate equipment to measure the conditions on a regular basis.
Environmental influences by printer
Condition
Exhaust air production
1,500 m
3
per hour / 91,535,616 in
3
per hour
Heat production 13 kW
Moisture production 300 mL per hour - 400 mL per hour
Print room conditions
434
Chapter 15 - References