EasyManuals Logo

Quanta Computer T5016-LB8D User Manual

Default Icon
1523 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1034 background imageLoading...
Page #1034 background image
UANTA COMPUTER INC.
Layer 2/3/4 Managed Switch
_____________________________________________________________________________
LB9 User’s Guide 1034/1523
11.2.6.6 Configuring Hosts configuration Page
Configurable Criteria
Host - This is a list of the hosts that have been configured for syslog. Select a host for changing the
configuration or choose to add a new hosts from the drop down list.
IP Address or Hostname - IP address or Hostname of the remote host for syslog. Available only
during addition of a new Host. Host Names are composed of series of labels concatenated with dots.
The labels must start with a letter, end with a letter or digit, and have as interior characters only
letters, digits, and hyphen. Each Label must be 63 characters or less, and the entire Host name has
a maximum of 255 characters. Refer RFC 1034 (3.5. Preferred name syntax) for specifying the Host
names.
Severity Filter -A log records messages equal to or above a configured severity threshold. Select
the severity option by selecting the corresponding line on the pull-down entry field. These severity
levels have been enumerated below:
 Emergency (0): system is unusable
 Alert (1): action must be taken immediately
 Critical (2): critical conditions
 Error (3): error conditions
 Warning (4): warning conditions
 Notice(5): normal but significant conditions
 Informational(6): informational messages
 Debug(7): debug-level messages
IP Address Type - This is the IP address of the host configured for syslog.
Port -This is the port on the host to which syslog messages are sent. The default port is 514. Specify
the port in the text field.
Non-Configurable Data
Status -This specifies whether the host has been configured to be actively logging or not.
Command Buttons
Submit - Update the switch with the values you entered.
Refresh - Refresh the database and display it again starting with the first entry in the table.
Delete - Delete a configured host.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quanta Computer T5016-LB8D and is the answer not in the manual?

Quanta Computer T5016-LB8D Specifications

General IconGeneral
BrandQuanta Computer
ModelT5016-LB8D
CategorySwitch
LanguageEnglish