UANTA COMPUTER INC.
Layer 2/3/4 Managed Switch
_____________________________________________________________________________
LB9 User’s Guide 1035/1523
11.2.6.7 Configuring Terminal Log Configuration Page
This allows logging to any terminal client connected to the switch via telnet or SSH. To receive the log
messages, terminals have to enable "terminal monitor" via CLI command.
Configurable Criteria
Admin Status -A log that is "Disabled" shall not log messages to connected terminals. A log that is
"Enabled" shall log messages to connected terminals. Enable or Disable logging by selecting the
corresponding line on the pull-down entry field.
Severity Filter - A log records messages equal to or above a configured severity threshold. Select
the severity option by selecting the corresponding line on the pull-down entry field. These severity
levels have been enumerated below:
 Emergency (0): system is unusable
 Alert (1): action must be taken immediately
 Critical (2): critical conditions
 Error (3): error conditions
 Warning (4): warning conditions
 Notice(5): normal but significant conditions
 Informational(6): informational messages
 Debug(7): debug-level messages
Command Buttons
Submit - Update the switch with the values you entered.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quanta Computer T5016-LB8D and is the answer not in the manual?

Quanta Computer T5016-LB8D Specifications

General IconGeneral
BrandQuanta Computer
ModelT5016-LB8D
CategorySwitch
LanguageEnglish