11.3.2.6 Configuring Error Disable Recovery
Selection Criteria
storm-control - Enables or disables the specify Error Disable Recovery Cause by storm-control.
The factory default is disabled.
udld - Enables or disables the specify Error Disable Recovery Cause by UDLD. The factory default
is disabled.
Configurable Data
Error Disable Recovery Interval - This specifies the interval value for Error Disable Recovery. The
factory default is 300 seconds. The range of Interval is (30 to 86400).
Non-Configurable Data
Interface - This specifies the interface which is shut down by Error Disable.
ErrDisable Reason - This specifies the reason why this interface is shutdown.
Time Left (sec) - This specifies the left time of this interface will be enabled.
Command Buttons
Submit - Update the switch with the values on this screen. If you want the switch to retain the new
values across a power cycle, you must perform a save.
Refresh - Refresh the data on the screen with the present state of the data in the switch.