894User Manual 1175.7068.02 ─ 12
TRACe<n>:IQ:AVERage:COUNt <NumberSets>
This command defines the number of I/Q data sets that are to serve as a basis for
averaging.
Suffix:
<n>
.
irrelevant
Parameters:
<NumberSets> 0 to 32767
*RST: 0
Example:
TRAC:IQ ON
Switches on acquisition of I/Q data.
TRAC:IQ:AVER ON
Enables averaging of the I/Q measurement data
TRAC:IQ:AVER:COUN 10
Selects averaging over 10 data sets
TRAC:IQ:DATA?
Starts the measurement and reads out the averaged data.
Usage: SCPI confirmed
TRACe<n>:IQ:AVERage[:STATe] <State>
The command enables averaging of the recorded I/Q data, provided that I/Q data
acquisition was previously enabled with TRACe<n>:IQ[:STATe] on page 898.
With I/Q data averaging enabled, the maximum amount of I/Q data is limited to 512kS
(524288 complex samples).
Suffix:
<n>
.
irrelevant
Parameters:
<State> ON | OFF
*RST: OFF
Example:
TRAC:IQ ON
Switches on acquisition of I/Q data.
TRAC:IQ:AVER ON
Enables averaging of the I/Q measurement data.
TRAC:IQ:AVER:COUN 10
Selects averaging over 10 data sets.
TRAC:IQ:DATA?
Starts the measurement and reads out the averaged data.
Remote Commands in I/Q Analyzer Mode

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the R&S ESR Series and is the answer not in the manual?

R&S ESR Series Specifications

General IconGeneral
BrandR&S
ModelESR Series
CategoryReceiver
LanguageEnglish

Related product manuals