OfficeServ 7100 PROGRAMMING
TECHNICAL MANUAL PART 2 SEPTEMBER 2008
MMC: 841
No Option Description Default
Sets CTI link via LAN option with the system. -
0 SMDR REPORT: Sets YES or NO for SMDR data to CTI link via
LAN.
NO
1 UCD REPORT: Sets YES or NO for UCD data to CTI link via
LAN.
NO
4 CTI LINK OPTION
2 ALIVE TIME: This is a CTI link via LAN alive check timer. If
this sets 0, the system will not check link alive.
300 SEC
Sets IP phone DSP parameters of system-wide. -
0 M-FRAME: This value determines the transmission interval
time of VoIP packets generated by the IP phone. This data
is effective only when DOWN = SYS DATA in this MMC.
The range is 10~40 ms. Applies only to ITP to ITP calls
(when both ITPs are in same zone).
10 ms
1 JITTER: Decides the minimum time to consider delay for
jitter adjustment. This data is effective only when DOWN =
SYS DATA in this MMC. The range is 10~90 ms. Applies
only to ITP to ITP calls (when both ITPs are in same zone).
20 ms
2 TOS: An eight-bit binary value that will be utilized by
external routers, switches, etc(that optionally support TOS-
bit prioritization)-to identify the transport-priority value of
data packets generated by the IP phone. This value can
be left at default value(00000) if your network infrastructure
does not support this method of bandwidth management.
This data is effective only when DOWN = SYS DATA in this
MMC. Applies only to ITP to ITP calls (when both ITPs are
in same zone).
all bits 0
3 CONTROL;
1 SYS BASE
2 ITP BASE
4 CODEC
1 MGI FIRST
2 ITP FIRST
SYS BASE
MGI FIRST
5 ITP DSP PARA
3 DOWN: Determines data uses system-wide data or each
phone data for IP-based phone DSP control.
a) SYS DATA: System-wide data will be used.(MMC 841
data)
b) PHONE DATA: Each phone data will be used.(MMC
840 data)
SYS DATA