OfficeServ 7100 PROGRAMMING
TECHNICAL MANUAL PART 2 APRIL 2007
MMC: 852
4. Press UP or DOWN to select desired option
OR
16:MJC05 AC:OFF
AC Pwr Loss
Press TRANSFER to return to normal display
OR
press SPEAKER to advance to next MMC.
DEFAULT DATA: ALL OFF
RELATED ITEMS MMC 501 SYSTEM TIMERS (ALARM REMINDER INTERVAL,
ALARM REMINDER RING OFF TIMERS)
MMC 722 STATION KEY ASSIGNMENT
MMC 723 SYSTEM WIDE KEY ASSIGNMENTS
MMC 851 SYSTEM ALARM REPORTING
MMC 853 MAINTENANCE BUSY
ALARM CODE DEFINITIONS
ALM
NO.
ALM
CODE
ALARM DEFINITION
01 MJA01 POR Restart
MP restart process has been executed
via power on restart (POR).
02 MJA02 Button Restart
MP restart process has been executed
via button reset or MMC 811.
03 MJA03 Mem Reset
The system RAM has been cleared via
manual programming Web
Management resulting in a system
reset.
04 MJA04 Watchdog Reset The MP has reset (Watchdog Reset)
05 MJA05 LCP Reset An LCP has reset
06 MJA06 PCM Switching
A fault has occurred in the Switching
Control.
MJA10 S/W Exception Err Other kinds of System Restarts
08 MJB01 HDLC Com Error
Communications to Expansion Control
Processor lost or faulty.
09 MJB02 Memory Alarm 1
A RAM diagnostic check error has
occurred in the MP.
10 MJB03 Memory Alarm 2
11 MJB04 Memory Alarm 3
12 MJB05 Memory Alarm 4
13 MJB06 IPC MSGQ Over The IPC message queue is over 80% full
14 MJB07 Task MSGQ Over
The IPC message queue is now back
under 80% full
15 MJC01 DTMF Fault
An abnormal interrupt has occurred in
the system DTMF resources.