OfficeServ 7100 PROGRAMMING
TECHNICAL MANUAL PART 2 APRIL 2007
MMC: 852
ALM
NO.
ALM
CODE
ALARM DEFINITION
16 MJC02 Tone Fault
An abnormal interrupt has occurred in
the system tone resources. IE busy,
ringback, error, no more calls etc.
17-23 NOT USED
24 MJC10 AA-DTMF Fault
An abnormal fault reported in one of the
systems AA card DTMF resources.
25 MJC11 AA-DTMF Rec
An abnormal fault reported in one of the
systems AA card DTMF resources has
recovered.
26 MJC12 E911 Restart An E911 card has rebooted
27 MJC13 E911 Block An E911 card could not be accessed
28-29 NOT USED
30 MJC16 WLI Restart The WLI card has restarted
31 MJC17 WLI Block The WLI card could not be accessed
32 MJD01 Sync Failure
Clocking on PRI cards has become
asynchronous.
33 MJD02 Sync Recovery
Clocking on PRI cards has become
synchronous.
34 MJD03 Red Alarm
Locally detected loss of PCM carrier on
PRI card for more than 250 ms.
Alarm Data = Cabinet, Slot (C1,2) (S1
through 10)
35 MJD04 Red Alarm Rec
PCM carrier detected locally on PRI
cards.
Alarm Data = Cabinet, Slot (C1,2) (S1
through 10)
36 MJD05 Yellow Alarm
Remotely detected failure transmitted in
frame on PRI card.
Alarm Data = Cabinet, Slot (C1,2) (S1
through 10)
37 MJD06 Yellow Alarm Rec
Remotely detected failure restored
transmitted on PRI card.
Alarm Data = Cabinet, Slot (C1,2) (S1
through 10)
38 MJD07 Blue Alarm
All one's being transmitted on facility on
PRI card.
Alarm Data = Cabinet, Slot (C1,2) (S1
through 10)
39 MJD08 Blue Alarm Rec
A blue alarm condition has been
cleared.
Alarm Data = Cabinet, Slot (C1,2) (S1
through 10)