OfficeServ 7100 PROGRAMMING
TECHNICAL MANUAL PART 2 APRIL 2007
MMC: 852
ALM
NO.
ALM
CODE
ALARM DEFINITION
40 MJD09 Bit Error Alarm
Alarm is activated when the when error
rate exceeds 1x10
-6
errors. Note: 1x10
-6
is threshold for minor alarm, 1 x 10
-3
is
threshold for major alarm errors on PRI
or BRI..
Alarm Data = Cabinet, Slot (C1,2) (S1
through 10)
41 MJD10 NTWRK Event
An Implausible event has occurred on
the PRI or BRI Network digital line.
Protocols do not match or subscriber ID
mismatch.
Alarm Data = Cabinet, Slot (C1,2) (S1
through 10)
42 MJD11 SPID Init Err
The BRI received an error from the
network
Alarm Data = Cabinet, Slot Channel
(C1,2)
(S1 through 10),Channel(1 through 16)
43 MJD12 SPID Init Rec
The BRI has recovered from an error on
the network
Alarm Data = Cabinet, Slot Channel
C1,2
(S1 through 10),C (1 through 16)
44 MJD13 LPBK Error
Internal on demand loopback failed.
Alarm Data = Cabinet, Slot Channel
(C1,2)
(S1 through 10), (C1 through 24)
45 MJD14 LPBK Recovery
Internal on demand loopback test
passed.
Alarm Data = Cabinet, Slot Channel
(C1,2)
(S1 through 10), (C1 through 24)
46 MJD15 BRI DL Unavail
A BRI data link is out of service.
Alarm Data = Cabinet, Slot Channel
(C1,2)
(S1 through 10), (C1 through 16)
47 MJD16 BRI DL Recovered
A BRI data link is back in service.
Alarm Data = Cabinet, Slot Channel
(C1,2)
(S1 through 10), (C1 through 16)
48 MJD17 RAM Error
An error has occurred in the T1/PRI or
BRI card RAM.
Alarm Data = Cabinet, Slot (C1,2) (S1
through 10)
49 MJD18 T1 Restart
The T1 card has restarted
Alarm Data = Cabinet, Slot (C1,2) (S1
through 10)
Home Page