EasyManua.ls Logo

Siemens HiPath 1120 - Figure 4-21 ADSL Connection on the Hipath1150;1190;1190 R; Installing a Baby Board ADSL Module; On the Hipath 1120

Siemens HiPath 1120
389 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Manual
4-151
Installation
Installing modules
Connections diagram on the HiPath1150/1190/1190R
Figure 4-21 ADSL Connection on the HiPath1150/1190/1190R
4.7.6 Installing a Baby Board ADSL module
4.7.6.1 On the HiPath 1120
Installation Procedures
Step Procedure
1. Select the SLIMC module.
2. Attach the separators provided with the module.
3. Attach the Baby Board ADSL module to the separators.
4. Connect the cable of the Ethernet Interface to the X6 Connectors.
5. Connect the cable of the ADSL line to the X14 Connectors.
6. Connect the power cable of the module Baby Board ADSL to the X7 Connectors.
7. “Performing a visual inspection” on page 4-189.
8. Configure the required data (see “Operation” on page 7-278).