System Data
2-34 Service Manual
System expansion limitations
Table 2-5 Considerations on TME1 digital lines on the HiPath 1190
2.5.2 Considerations on system telephones
HiPath 1120
The table below shows the settings available for KS phones and optiPoint using U
P0/E MODULES
:
Table 2-6 optiPoint and KS telephones for HiPath 1120.
Limitations:
The limit for KS telephones operating with optiPoint telephones in the system is 2 (KS).
1 TME1 + 1 EB 800 8 30 38
2 TME1 + 1 EB 800 8 37 45
1 TME1 + 1 EB 800 + 1 EB 200 10 30 40
2 TME1 + 1 EB 800 + 1 EB 200 10 35 45
1 TME1 + 1 EB 800 + 1 EB 400 12 30 42
2 TME1 + 1 EB 800 + 1 EB 400 12 33 45
1 TME1 + 2 EB 800 16 29 45
2 TME1 + 2 EB 800 16 29 45
1 TME1 + 2 EB 800 + 1 EB 200 18 27 45
2 TME1 + 2 EB 800 + 1 EB 200 18 27 45
1 TME1 + 2 EB 800 + 1 EB 400 20 25 45
2 TME1 + 2 EB 800 + 1 EB 400 20 25 45
1 TME1 + 3 EB 800 24 21 45
2 TME1 + 3 EB 800 24 21 45
1 TME1 + 3 EB 800 + 1 EB 200 26 19 45
2 TME1 + 3 EB 800 + 1 EB 200 26 19 45
1 TME1 + 3 EB 800 + 1 EB 400 28 17 45
2 TME1 + 3 EB 800 + 1 EB 400 28 17 45
1 TME1 + 4 EB 800 32 13 45
2 TME1 + 4 EB 800 32 13 45
1 TME1 + 5 EB 800 40 5 45
2 TME1 + 5 EB 800 40 5 45
1 TME1 + 10 EB 400 40 5 45
2 TME1 + 10 EB 400 40 5 45
Master/Slave/KS
None U
P0/E
(2 Ports) U
P0/E
(4 Ports)
0/0/4 2/2/2 4/4/2