Service Manual
3-75
Modules
Expansion modules (EB)
Segment Display Readings (H801) (E1 CAS access)
Table 3-20 TME1 module display readings (CAS access)
Display Reading Meaning
8
Continuous The module is powered.
]
Continuous Starting TME1 module.
E
Continuous
Waits 10 seconds for a command from the software (E1
Trunk Manager). If it receives no command after the specified
time, the system resumes its usual operation.
8
Continuous Transferring memory contents to DRAM memory.
Continuous Checking and validating contents of Flash memory.
P
Continuous TME1 module is active but CAS link is out of service.
A
Continuous TME1 module is active with CAS link.
I
Continuous
“Unpacking” E1 Trunk Manager.
3
Continuous
7
Continuous Writing software to Flash memory.
F
Continuous Checking transferred data.
o
Continuous E1 and CAS links are down. The reason is unknown.
Cycle - Live Clearing Flash memory.
f e
Alternating Flash memory cleared.
h
Continuous
No software in Flash memory. Waiting for tool to download
software
A.
Continuous
The local interface is taking the clock as reference from this
link.
3