EasyManua.ls Logo

Siemens HiPath 1120 - Table 2-10 Technical Data; Technical Standards and Compliance

Siemens HiPath 1120
389 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Manual
2-39
System Data
Technical standards and compliance
*Values vary according to the country. The values shown are specifically for Brazil.
**Values depend on the country settings, which are configurable. The values shown are default values for Brazil.
Table 2-10 Technical Data
2.7 Technical standards and compliance
*Weather conditions: Operation 3K3 Transportation 2K4 Storage 1K3.
Mechanical: Operation 3M3 Transportation 2M2 Storage 1M2.
Table 2-11 Standards and compliance
Open loop isolation
resistance between A/B or a/
ground or b/ground
> 10MΩ
Closed loop line resistance/
continuous loop current
Complies with national requirements/standards
Incoming Call Detection > 9V
RMS
Values shown are approximate. When making connections, consider the specific
level of tolerance that applies.
Compliance Standard Note
Electrical Safety
EN60950
IEC 60950
UL 60950-1
Environmental Conditions IEC 721 *
Power Surge
IEC61000-4-5
(IEC 801-5)
TIA-968-A
Level 3
Fast Transients
IEC61000-4-4
(IEC 801-4)
Level 3
Static electricity discharge
IEC61000-4-2
(IEC 801-2)
Air - Level 3 (8kV)
Contact - Level 2 (4kV)
Element HiPath 1120 HiPath 1150 HiPath 1190