EasyManua.ls Logo

Siemens HiPath 1120 - External Line Settings

Siemens HiPath 1120
389 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring the system specifically for the client
6-210 Service Manual
Table of the Systems Programming Codes
6.2.2 External line settings
Programmed
Functions
Code Intermediate data Data to be
programmed
Completing
data entry
Default
Groups of external
lines
156 group of external lines External line # instead of
group
0
Seizure priority by
type of external
line
194 1 - Standalone
2 - Digital
3 - Analog
automatic 1 - Standal-
one
external analog line
seizure protocol
017 external analog line 1 - Loop seizure
2 - Ground seizure
# instead of
external line
2 - Canada
1 - Other
countries
Caller ID for analog
lines (CLIP)
005 external analog line 0 - Disabled
1 - DTMF1
2 - DTMF2 (off hook)
3 - FSK
# instead of
external line
1 - Brazil,
China, Peru,
India, IM-
Spain and IM-
English
2 - Russia
3 - Other
countries
external Line Call
Direction
155 External line 1 - Bidirectional
2 - Incoming unidirectional
3 - Outgoing unidirectional
# instead of
external line
1 - Bidirec-
tional
Flash Duration in
analog line
118 external analog line 05 to 99
05 - 50 ms
99 - 990 ms
# instead of
external line
Country
*
Reseizure time for
external line
129 05 to 99
05 - 500ms
99 - 9900ms
Automatic 05
Maximum time
between rings for
an incoming call
117 05 to 20 seconds Automatic 13 seconds
for Argentina
4 seconds for
Korea
06 seconds
for the other
countries
Coefficient for an
external Analog
Line
147 external analog line 1 - Standard line, 900 Ω
2 - 600 Ω line
3 - Short line
4 - Long line
# instead of
external line
1 - Standard
line
Type of Answering
Signal
**
158 external analog line 0 - None
1 - Polarity Reversal
2 - DTMF Tone
# instead of
external line
0 - None
Tone detector 160 external analog line
- Yes
# - No
# instead of
external line
- Yes
external line
connection.
133 group of external lines 1 - Direct
2 - Satellite PABX
# instead of
external line
1 - Direct