Service Manual
6-229
Configuring the system specifically for the client
Table of the System’s Programming Codes
Table 6-19 EVM module
Message source 208 1 - Message 1
or
2 - Message 2
Port: 7491 or 7492 # instead of a
mailbox
None
Message Mode 209 1 - Message 1
or
2 - Message 2
1 - Continuous
or
2 - Single
# instead of a
mailbox
1 - Continu-
ous
Optional message
for MSN
210 Position: 001 to 140 1 - Message 1
or
2 - Message 2
# instead of a
mailbox
None
System number 211 Number up to 10 digits 5-second
timeout
None
Type of system
number
212 1 - Unknown
2 - System Number
3 - Local Area Code (LAC)
4 - Country Code
Automatic 3 - Italy
1 - Other
countries
Sensor message
(HiPath 1120)
213 1 - Message 1
or
2 - Message 2
Automatic None
Type of voice mail 214 1 - None
2 - VMI
3 - EVM
Automatic 1
Voice mail group 215 UCD Group or * to delete Automatic None
Mailbox assign-
ment for auto-
answering mode
216 Mailbox 1 or 2 Greeting message port:
7491 or 7492
# instead of a
mailbox
None
Audio quality 228 1 - Best - for greetings and
messages
2 - High quality for greet-
ings/Best for messages
3 - High quality for greet-
ings and messages
Automatic 2 - High qual-
ity for greet-
ings/Best for
messages
Message/Greeting
for an external
analog line
230 external analog line 1 - Message 1
or
2 - Message 2
# instead of
trunk
None
Programmed
Functions
Code Intermediate data Data to be
programmed
Completing
data entry
Default