Installation
4-160 Service Manual
Installing modules
4.7.9.3 On the HiPath 1190/1190R
Installation Procedures
Assembly Diagram
Figure 4-30 Installing a CTR- U
P0/E
module on the HiPath 1190/1190R
Step Procedure
1. Turn off the power supply.
2. Remove the system’s front cover.
3. Disconnect the Main Distribution Frame’s cables from the MB.
4. Move the module’s latch as shown in figure 4-12.
5. Remove the MB.
6. Attach the module to the corresponding Connector on the CPU
7. Insert the MB into the system.
8. Move the module latch back to secure module.
9. Connect the Main Distribution Frame’s cables.
10. Reassemble the entire set.
11. “Performing a visual inspection” on page 4-189.
12. Turn on the power supply.
13. Configure the required data (see “Operation” on page 7-278).