Service Manual
6-233
Configuring the system specifically for the client
Table of the System’s Programming Codes
6.2.14 Relay and sensor on the HiPath 1120
Table 6-23 Relay and sensor on the HiPath 1120
Programmed
Functions
Code Intermediate data Data to be
programmed
Completing
data entry
Default
Sensor function
configuration
170 0 = Deactivate the
sensor’s function (default)
1 = Dial the number speci-
fied in "Number dialed by
sensor activation" (Code
052).
2 = Activate the relay
through the sensor
3 = Detect DTMF code.
When this setting is
selected, the number that
was called must acknowl-
edge or ignore an alarm
call by sending an
acknowledgement code
(ā€œ#ā€ DTMF signal)
Automatic 0
Sensor Activation
Logic
174 0 - Contacts closed
1 - Contacts open
# instead of
the sensor
0 - Contacts
closed
Time between
attempts for acti-
vating the sensor
050 Time: 00 to 10 minutes Automatic 03 (3
minutes)
MSN assignment
for the sensor
051 Position: 001 to 140 or
āˆ— - to delete
Automatic None
Number dialed by
sensor activation
052 Number (up to 20 digits) Automatic or
#
None
Number of
attempts for acti-
vating the sensor
053 001 to 100 (attempts) Automatic 001 (1
attempt)
DTMF signals for
the sensor
177 Number (up to 20 digits)
# - To confirm
Automatic or # None
Relay
*
* When playing music from an external music source, all regulations relating to copyrights for the country in question have
to be followed.
175 1 - Switch
2 - Monoflop
3 - Invert
4 - Music on Hold
5 - External signal
Automatic 1 - Switch
Timer for deactivat-
ing the relay
173 000 to 255
(intervals of 0.5 s)
# instead of
number
002 - (1
second)
External ring for
activating the relay
071 extension Automatic None