Operation
7-362 Service Manual
HiPath 1100 applications
7.4.6 E1 Trunk Manager
The E1 Trunk Manager is an administrative program for configuring a TME1 module with E1
CAS access.
Hardware Requirements:
– Serial interface communications (COM port).
General Information:
With the E1 Trunk Manager you can do the following:
Download software and databases
Remove traces
Select the software’s type of connection to the module (local or via modem)
Select a COM port
Select a Country when installing the program, including the appropriate protocol and CAS
signaling (e.g., line signaling (1bit-E&M and 2bit-R2), and record signaling (DP, DTMF and
MFCR2)).
For further details on how to configure a TME1 module with E1 CAS access refer to the
program’s “Help” system.
If the module does not initialize, check its status on the 7-segment display (see
“TME1 module” on page 3-69).