6-265
Configuring the system specifically for the client
Comments about the system’s programming codes
Dialed number (Number)
The system allows you to configure a feature that ensuring confidentiality of the number
dialed at the time the CDR record is issued. This replaces the numbers by the symbol “?”
Type of call (I):
1 = Incoming call
2 = Outgoing call
5 = Transferred incoming call
6 = Transferred outgoing call
7 = 3-way conference with incoming
8 = 3-way conference with outgoing call
* = Incoming call not answered yet = incoming call
Impulses (Call fees) with a TME1 module installed.
Cost Code (Account code).
Example
Table 6-25 CDR Header Layout
When a call is transferred, a new CDR record is created. The hold time at the external line is accounted for by the extension
that transferred the call.
Call Detail Report with a Serial Interface (006)
This setting specifies that the Call Detail Report will be done through a serial interface.
Date Time Ln Ext WCOS Ring Duration Number I Call fees Acc. code
22.11.99 14:00:00 01 21 00:14 00:01:34 2222222 1
In the event of a power outage during ticketing, all tickets that were being sent when
the power outage occurred are re-sent when a connection is re-established.
Example:
1. If 300 tickets are stored in the memory, the user establishes a new connection,
sends 100 tickets and terminates the connection.
2. Then the user establishes new connection to send the remaining 200 tickets, but
a power outage occurs.
3. After the power outage, once the user resumes his/her work, a new connection
is established. During this connection all 200 tickets that were being sent when
the power outage occurred are re-sent.