Configuring the system specifically for the client
6-258 Service Manual
Comments about the system’s programming codes
Module Detection (061)
This setting specifies the slots to which new modules are connected, so that the system may detect them.
The modules can only be connected/disconnected when the system is turned off.
If the “Detect all slots” option is selected, the system will detect the components in the following order :
1 - External lines/digital extensions
2 - External lines/analog extensions
This means that if a numbering sequence for analog lines/extensions has been previously configured it will be changed when
an S0 module or a TME1 module is added.
Example: In a HiPath 1150 system that has only a MB module (2 external lines and 10 analog
extensions) the numbering pattern will be 801 and 802 for the external analog lines, and 11 to
20 for the analog extensions. Inserting an S0 module produces the following configuration:
- 801 to 805 for the digital lines
- 806 and 807 for the external analog lines
- 11 to 15 for the ISDN extensions
- 16 to 25 for analog extensions
- Extension 16 is now the Programming extension.
If “Detect only specified slot” is selected, the existing numbering configuration will remain. Only the module will be detected
by the system.
Type of MSN Signal (073)
This setting lets you choose one of the four types of rings for various calls, and a ring for registered MSNs. The default config-
uration for MSNs is Type 1 ring.
Reference Clock (090)
This allows you to specify a module slot for the system’s Reference Clock.
Assigning a Temporary MSN (093)
This feature allows you to use a temporary MSN from your own directory to make an external call. Or, to use the "Key Assign-
ment" feature to assign a key to an MSN for monitoring incoming and outgoing calls (see Key Assignment - Using a Temporary
MSN for Making a Call, in the User Manual).
MSN Identification Mode (224)
This setting specifies how the MSN is shown on a system telephone display. In the default configuration no Mode is config-
ured.
The modules can only be connected/disconnected when the system is turned off.