Selection Function
Create software backup A backup of the system CompactFlash card is saved to the user
CompactFlash card or USB FlashDrive.
NCK default data The system loads the Siemens NCK data default settings and de‐
letes the retentive data on the PLC.
Drive default data The SINAMICS user data is deleted.
PLC default data PLC general reset and load default NOP PLC program.
HMI default data Selection between two cases: No [Case 1]/ Yes [Case 2]
● Case 1:
User data in the /user directory is deleted.
● Case 2:
As case 1 and additionally:
Deletion
of the data
in the /oem and /addon directories - except
the logbook data.
Factory settings Selection between two cases: No [Case 1]/ Yes [Case 2]
● Case 1:
The SINAMICS user data is deleted.
Siemens standard NCK data is loaded.
PLC general reset and load default NOP PLC program.
User data in the /user directory is saved.
● Case 2:
As case 1 and additionally:
Deletion of the data
in the /oem and /addon directories - except
the logbook data.
Delete OEM files All additional machine manufacturer data is deleted.
Delete user files
PLC stop The PLC is stopped.
Checking the hardware
The technology is determined during startup for the SINUMERIK PPU 2xy.3. This distinction
is made using the article number found in the hardware information block, which is then
compared with the existing NCK scaling.
The following message is output if software that is not suitable for this hardware is found:
Scope of delivery and requirements
1.4 Starting up the control
CNC commissioning
18 Commissioning Manual, 10/2015, 6FC5397-3DP40-5BA3