Chapter 12 — Library Troubleshooting Restoring the Library Configuration
November 2016 User Guide—Spectra T950 Library
389
4. ClickNexttoadvancethroughthepartitionconfigurationscreensuntil
youreachtheChambersandDrivesscreen.
5. Decreasethenumberofstoragechambersassignedtothepartitionby
thenumberofmissingmagazines.
6. ClickNexttoadvancethroughtheremainderofthescreenswithout
makinganyadditionalchangesuntilyoureachtheSaveLibrary
Configurationscreen.
7. ClickSave.TheShareLibraryServicesscreenredisplays.
8. RepeatStep2onpage388throughStep6,thistimeincreasingthe
numberofstoragechambersassignedtothepartitiontotheoriginal
number.Themagazinesinthefreepoolarereassignedtothepartition.
Figure 252 The Chambers and Drives screen.
If the library has multiple partitions and you imported magazines into all of the
partitions after the configuration backup file you used to restore the library was
generated, the magazines can potentially end up in the wrong partition. Carefully
examine the cartridge inventory for each partition. Export any wrongly assigned
magazines and reimport them into the correct partition.