Chapter 13 — Drive Troubleshooting Troubleshooting Drives
November 2016 User Guide—Spectra T950 Library
412
LTO SCD Codes
SCD Code Descriptions for LTO-3 and Later Generations Thefollowing
tableshowstheSCDcodesand,whereapplicabletheassociatedDLM
DriveHealthicon,forLTO‐3andlatergenerationsofLTOdrives.Seethe
tableonpage325foradescriptionofwhattheDriveHealthiconsindicate.
ForTS11x0technologyMCDcodes,seeTS11x0TechnologyMCDCodeson
page422.
Note: Thesingle‐characterdisplaydoesnotusethecharactersB,D,G,
I,OandZtopreventmisinterpretationasthecharacters8,0,6,2,
and1.
Code DLM
Health
Icon
Cause and Solution
0 Noerroroccurred.Noactionisrequired.
Thepowerwascycledordiagnosticsfinishedwithnoerrors.
1 Coolingproblem.
Therecommendedoperatingtemperaturewasexceeded.Performoneormoreof
thefollowing:
Makesurethatthecoolingfanisrotatingandisquiet.
Removeanyblockagethatpreventsairfromflowingfreelythroughthedrive.
Makesurethattheoperatingtemperatureandairflowiswithinthespecified
range(refertothetapedrivedocumentationforthesespecifications).
Iftheoperatingtemperatureiswithinthespecifiedrangeandtheproblem
persists,contactSpectraLogicTechnicalSupport(seeContactingSpectraLogic
onpage7).
Note: Theerrorcodeclearswhenyouresetorpowercyclethedriveorwhen
youplaceitinmaintenancemode.
2 Powerproblem.
Theexternallysuppliedpowerisapproachingthespecifiedvoltagelimits(the
driveisstilloperating)orisoutsidethespecifiedvoltagelimits(thedriveisnot
operating).
Iftheproblemisonlyexhibitedbyonedriveinthelibrary:
Makesurethatthelibrary’spowerconnectorisproperlyseated.
Iftheproblempersists,contactSpectraLogicTechnicalSupport(see
ContactingSpectraLogiconpage7).
Note: Theerrorcodeclearswhenyouresetorpowercyclethedriveorwhen
youplaceitinmaintenancemode.
Iftheproblemisexhibitedbymultipledrivesinthelibrary:
Thepowerthroughoutthelibraryneedstobechecked.ContactSpectraLogic
TechnicalSupportforassistance(seeContactingSpectraLogiconpage7).