Chapter 13 — Drive Troubleshooting Troubleshooting Drives
November 2016 User GuideSpectra T950 Library
417
A Degradedoperation.
Thedrivedeterminedthataproblemoccurredthatdegradedtheoperationof
thedrive,butitdidnotrestrictcontinueduse.
Thedriveisusable,thoughthesinglecharacterdisplay(SCD)continuesto
indicateanerrorandthestatuslightflashesamber.Theerrorcodemayclear
whenyoucycle
powertothedrive.
1. Resetthedrive(seeResettingaDriveonpage395)tocleartheerrorcode.
2. Confirmthatthedriveisusingthecurrentfirmwareversion(seeUpdating
DriveFirmwareonpage468)andupdatethefirmwareifnecessary.
3. UsetheDriveHealthVerificationwizardtotestthedrive(seeUsingDLMto
TestaDriveonpage427).
4. Iftheproblempersists, contactSpectraLogicTechnicalSupport(see
ContactingSpectraLogiconpage7).
C Cleaningindicator.
Thedriveneedstobecleaned,orisintheprocessofloadingthecleaning
cartridgeorbeingcleaned.Theerrorcodeclearswhenyoucleanthedriveand
unloadthecleaningcartridge.SeeCleaningaDriveonpage461forinstructions.
d TwodrivesontheFibreChannelloophavethesameArbitratedLoopPhysical
Address.
E TheFibreChannelportconnectionisoffline.
e Thedrivedetectedaconfigurationerrorduringanencryptionoperation.
1. MakesurethatyouareusingLTO4orlatergenerationdatacartridges.
EncryptionisonlysupportedforLTO4andlatergenerationcartridges.
2. Retrytheencryptionoperationwiththesuspectcartridgeinanother
encryptionenableddrive.
3. Replacethecartridgeifyouseethesameprobleminmultipledrives.
F DriveFiberCableerror.
TheFibreChanneldrivedoesnotdetectlightorarelateddiagnosticfailedto
detectlightthroughthefiberopticconnectiontothedrive.
Verifythefibercablesandconnectionsbetweenthedriveandthehostarethe
correcttypeandareworkingproperly.Verifyallequipmentanddevicesare
poweredON.
Verifytheconfigurationsettingsforthedrivearesetcorrectlyandare
compatiblewiththetopologyofthenetwork.
Verifythatthehostfiberadapterandportareworkingproperlyandare
compatiblewiththetopologyofthenetwork.
VerifythattheFibreChannelswitchportsareworkingproperlyandare
compatiblewiththetopologyofthenetwork.
VerifythatthefibercableisconnectedtoPortA(0)ofthedrive.
VerifythatPortA(0)ontheFibreChanneldriveisworkingproperlybyusing
ITDTtorunthe“FunctionCode6:RunHostInterfaceWrapTest.