EasyManua.ls Logo

YASKAWA A1000

YASKAWA A1000
628 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
B.6 Defaults by Drive Model Selection (o2-04) and ND/HD (C6-01)
526 YASKAWA ELECTRIC SIEP C710616 27G YASKAWA AC Drive A1000 Technical Manual
Table B.11 400 V Class Drives Default Settings by Drive Capacity and ND/HD Setting
No.
<66> This parameter is available in models CIMR-A4A0930 and 4A1200.
Name Unit Default Settings
Model CIMR-A 4A0002 4A0004 4A0005 4A0007
C6-01 Drive Duty Selection
HD ND HD ND HD ND HD ND
0 1 0 1 0 1 0 1
o2-04 Drive Model Selection Hex. 92 93 94 95
E2-11 (E4-11) Motor rated Output kW 0.4 0.75 0.75 1.5 1.5 2.2 2.2 3.0
b3-04 V/f Gain during Speed Search % 100 100 100 100 100 100 100 100
b3-06 Output Current 1 during Speed Search 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
b3-07
<66>
Output Current 2 during Speed Search (Speed
Estimation Type)
b3-08
Current Control Gain during Speed Search (Speed
Est
imation Type)
0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
b3-26
<66> Start Speed Search Select
b8-03 Energy Saving Control Filter Time Constant s 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50
b8-04 Energy Saving Coefficient Value 576.4 447.4 447.4 338.8 338.8 313.6 313.6 265.7
C5-17 (C5-37) Motor Inertia
kgm
2
0.0015 0.0028 0.0028 0.0068 0.0068 0.0088 0.0088 0.0158
C6-02 Carrier Frequency Selection 1 7 1 7 1 7 1 7
E2-01 (E4-01) Motor Rated Current A 1 1.6 1.6 3.1 3.1 4.2 4.2 5.7
E2-02 (E4-02) Motor Rated Slip Hz 2.9 2.6 2.6 2.5 2.5 3 3 2.7
E2-03 (E4-03) Motor No-Load Current A 0.6 0.8 0.8 1.4 1.4
1.5 1.5 1.9
E2-05 (E4-05) Motor Line to Line Resistance 38.198 22.459 22.459 10.1 10.1 6.495 6.495 4.360
E2-06 (E4-06) Motor Leakage Inductance % 18.2 14.3 14.3 18.3 18.3 18.7 18.7 19
E2-10 (E4-10) Motor Iron Loss for Torque Compensation W 14 26 26 53 53 77 77 105
E5-01 Motor Code Selection (for PM Motors) Hex. 1232 1232 1233 1233 1235 1235 1236 1236
L2-02 Momentary Power Loss Ride-Thru Time s 0.1 0.1 0.2 0.2 0.3 0.3 0.5 0.5
L2-03 Momentary Power Loss Min
imum Baseblock Time s 0.2 0.3 0.3 0.4 0.4 0.5 0.5 0.5
L2-04 Momentary Power Loss Voltage R
ecovery Time s 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3
L3-24 Motor Acceleration Time for Inertia Calculations s 0.178 0.142 0.142 0.166 0.166 0.145 0.145 0.145
L8-02 Overheat Alarm Level C 110 110 110 110 110 110 110 110
L8-35 Installation Method Selection 2 2 2 2 2 2 2 2
L8-38 Carrier Frequency Reduction Selection 2 2 2 2 2 2 2 2
n1-03 Hunting Prevention Time Constant ms 10 10 10 10 10 10 10
10
n5-02 Motor Acceleration Time s 0.178 0.142 0.142 0.166 0.166 0.145 0.145 0.145
No. Name Unit Default Settings
Model CIMR-A 4A0009 4A0011 4A0018 4A0023
C6-01 Drive Duty Selection
HD ND HD ND HD ND HD ND
0 1 0 1 0 1 0 1
o2-04 Drive Model Selection Hex. 96 97 99 9A
E2-11 (E4-11) Motor rated Output kW 3.0 3.7 3.7 5.5 5.5 7.5 7.5 11
b3-04 V/f Gain during Speed Search % 100 100 100 100 100 100 100 100
b3-06 Output Current 1 during Speed Search 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
b3-07
<66>
Output Current 2 during Speed Search (Speed
Estimation Type)
––––––––
b3-08
Current Control Gain during Speed Search (Speed
Estimation Type)
0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
b3-26 <66> Start Speed Search Select
b8-03 Energy Saving Control Filter Time Constant s 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50
b8-04 Energy Saving Coefficient Value 265.7 245.8 245.8 189.5 189.5 145.38 145.38 140.88
C5-17 (C5-37) Motor Inertia
kgm
2
0.0158 0.0158 0.0158 0.0255 0.026 0.037 0.037 0.053
C6-02 Carrier Frequency Selection 1 7 1 7 1 7 1 7
E2-01 (E4-01) Motor Rated Current A 5.7 7 7 9.8 9.8 13.3 13.3 19.9
E2-02 (E4-02) Motor Rated Slip Hz 2.7 2.7 2.7 1.5 1.5 1.3 1.3 1.7
E2-03 (E4-03) Motor No-Load Current A 1.9 2.3 2.3 2.6 2.6 4 4 5.6
E2-05 (E4-05) Motor Line to Line Resistance 4.360 3.333 3.333 1.595 1.595 1.152 1.152 0.922
E2-06 (E4-06) Motor Leakage Inductance % 19 19.3 19.3 18.2 18.2 15.5 15.5 19.6
E2-10 (E4-10) Motor Iron Loss for Torque Compensation W 105 130 130 193 193 263 263 385
E5-01 Motor Code Selection (for PM Motors) Hex. FFFF FFFF 1238 1238 123A 123A 123B 123B
L2-02 Momentary Power Loss Ride-Thru Time s 0.5 0.5 0.5 0.5 0.8 0.8 1 1
L2-03 Momentary Power Loss Minimum Baseblock Time s 0.5 0.6 0.6 0.7 0.7 0.8 0.8 0.9
L2-04 Momentary Power Loss Voltage Recovery Time s 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3
L3-24 Motor Acceleration Time for Inertia Calculations s 0.145 0.154 0.154 0.168 0.168 0.175 0.175 0.265
L8-02 Overheat Alarm Level C 110 110 110 110 110 110 115 115
L8-35 Installation Method Selection 2 2 2 2 2 2 2 2