3.2 Component Names and Functions
142 YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
No. Name Function
E
LO/RE LED
Illuminated: The keypad controls the Run command (LOCAL Mode).
OFF: The control circuit terminal or serial transmission device controls the Run command (REMOTE
Mode).
Note:
• LOCAL: Operated using the keypad. Use the keypad to enter Run/Stop commands and the frequency
reference command.
• REMOTE: Operated from the control circuit terminal or serial transmission. Use the frequency
reference source entered in b1-01 and the Run command source selected in b1-02.
F
LO/RE Selection Key
Switches drive control for the Run command and frequency reference between the keypad (LOCAL) and
an external source (REMOTE).
Note:
• Stop operation to enable the LO/RE Selection Key when in Drive Mode. Set o2-01 = 0 [LO/RE Key
Function Selection = Disabled] to disable when switching from REMOTE to LOCAL will
have a negative effect on system performance.
• The drive will not switch between LOCAL and REMOTE when it is receiving a Run command from
an external source.
G
STOP Key
Stops drive operation.
Note:
The STOP key has highest priority. Push to stop the motor even when a Run command
(REMOTE Mode) is active at any external Run command source. Set o2-02 = 0 [STOP Key Function
Selection = Disabled] to disable the priority in .
H
Left Arrow Key Moves the cursor to the left.
Up Arrow Key/Down
Arrow Key
/
• Scrolls up or down to display the next item or the previous item.
• Selects parameter numbers, and increments or decrements setting values.
Right Arrow Key
(RESET)
• Moves the cursor to the right.
• Continues to the next screen.
• Clears drive faults.
ENTER Key
• Enters parameter values and settings.
• Selects menu items to move the user between keypad displays.
• Selects each mode, parameter, and set value.
I
RUN Key
Starts the drive in LOCAL mode.
Starts the motor tuning procedure in Auto-Tuning Mode.
Note:
Push on the keypad to set the drive to LOCAL Mode before using the keypad to operate the
motor.
J
USB Terminal
Insertion point for a mini USB cable. Uses a USB cable (USB standard 2.0, type A - mini-B) to connect
the keypad to a PC.
K RJ-45 Connector
Connects to the drive using an RJ-45 8-pin straight through UTP CAT5e extension cable or keypad
connector.
L Clock Battery Cover
Cover for the customer-supplied clock battery.
Note:
• Refer to “Replace the Keypad Battery” (page 437) for details on the battery models and installation
procedure.
• Make sure to prepare the clock battery. The clock battery is not supplied as accessories.
WARNING! Sudden Movement Hazard. The drive may start unexpectedly if switching control sources when setting b1-07 = 1
[LOCAL/REMOTE Run Selection = Accept Existing RUN Command]. Clear all personnel from rotating machinery and electrical
connections prior to switching control sources. Failure to comply may cause death or serious injury.