11
11.7 F: Options
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual 839
F5-05: Terminal P5-PC Function Select
No.
(Hex.)
Name Description
Default
(Range)
F5-05
(039D)
Terminal P5-PC
Function Select
Sets the function of terminal P5-PC on the DO-A3 option. Set F5-09 = 2
[DO-A3 Output Mode Selection = Programmable (F5-01 to F5-08)] to
enable this function.
6
(0 - 1A7)
F5-06: Terminal P6-PC Function Select
No.
(Hex.)
Name Description
Default
(Range)
F5-06
(039E)
Terminal P6-PC
Function Select
Sets the function of terminal P6-PC on the DO-A3 option. Set F5-09 = 2
[DO-A3 Output Mode Selection = Programmable (F5-01 to F5-08)] to
enable this function.
37
(0 - 1A7)
F5-07: Terminal M1-M2 Function Select
No.
(Hex.)
Name Description
Default
(Range)
F5-07
(039F)
Terminal M1-M2
Function Select
Sets the function of terminal M3-M2 on the DO-A3 option. Set F5-09 = 2
[DO-A3 Output Mode Selection = Programmable (F5-01 to F5-08)] to
enable this function.
F
(0 - 1A7)
F5-08: Terminal M3-M4 Function Select
No.
(Hex.)
Name Description
Default
(Range)
F5-08
(03A0)
Terminal M3-M4
Function Select
Sets the function of terminal M3-M4 on the DO-A3 option. Set F5-09 = 2
[DO-A3 Output Mode Selection = Programmable (F5-01 to F5-08)] to
enable this function.
F
(0 - 1A7)
F5-09: DO-A3 Output Mode Selection
No.
(Hex.)
Name Description
Default
(Range)
F5-09
(03A1)
DO-A3 Output Mode
Selection
Sets the output mode of signals from the DO-A3 option.
0
(0 - 2)
Refer to Table 11.51 for more information.
0 : Predefined Individual Outputs
1 : Binary Output
2 : Programmable (F5-01 to F5-08)
F6, F7: Communication Options
F6 and F7 parameters are used to set the basic communication settings and method of fault detection for the
communication option card. The communication option card parameters include common option card parameters
and communication protocol-specific parameters.
The following table lists the parameters that need to be set for each communication option card.
Refer to the technical manual for each communication option card for more information on installing, wiring, and
configuring the details needed before starting communication.
WARNING! Sudden Movement Hazard. Do test runs and examine the drive to make sure that command references are
configured correctly. If you set the command reference incorrectly, it can cause death, serious injury, or equipment damage from
unwanted motor rotation.
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV

Table of Contents

Other manuals for YASKAWA GA700

Related product manuals