10.16 T: Motor Tuning
596 YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
No.
(Hex.)
Name Description
Default
(Range)
Ref.
T1-11
(070B)
Motor Iron Loss
Sets the iron loss for calculating the energy-saving coefficient.
Determined by E2-
11 or E4-11
(0 - 65535 W)
1034
T1-12
(0BDB)
Test Mode
Selection
Sets the function to enable Test Mode after Stationary Auto-Tuning.
When you can operate the motor with a light load attached after
Stationary Auto-Tuning is complete, enable this parameter.
Note:
You must first set T1-10 [Motor Rated Slip Frequency] = 0 Hz to
enable this parameter.
0 : No
1 : Yes
0
(0, 1)
1035
T1-13
(0BDC)
No-load voltage
Sets the no-load voltage of the motor. If no-load voltage is necessary
at rated speed for the motor test report, set the voltage in this
parameter. If the motor test report is not available, do not change
this parameter.
Note:
To get the same qualities as a Yaskawa 1000-series drive or
previous models, set this parameter = T1-03 [Motor Rated
Voltage] value.
90% of T1-03
(200 V Class: 0.0 -
255.0 V, 400 V
Class: 0.0 - 510.0
V)
1035
◆ T2: PM Motor Auto-Tuning
No.
(Hex.)
Name Description
Default
(Range)
Ref.
T2-01
(0750)
PM Auto-Tuning
Selection
Sets the type of Auto-Tuning for PM motors.
0 : Manual Entry w/ Motor Data Sheet
1 : Stationary (Ld, Lq, R)
2 : Stationary (R Only)
3 : Z-Pulse Offset (Pole Position)
4 : Rotational (Ld, Lq, R, back-EMF)
0
(Determined by
A1-02)
1035
T2-02
(0751)
PM Motor Code
Selection
Sets the PM motor code for drives operating SMRA, SSR1, or
SST4-series Yaskawa PM motors.
Determined by A1-
02 and o2-04
(0000 - FFFF)
1036
T2-03
(0752)
PM Motor Type
Sets the type of PM motor the drive will operate.
0 : IPM motor
1 : SPM motor
1
(0, 1)
1036
T2-04
(0730)
PM Motor Rated
Power
Sets the rated output power (kW) of a PM motor.
Determined by o2-
04 and C6-01
(0.00 - 650.00 kW)
1036
T2-05
(0732)
PM Motor Rated
Voltage
Sets the rated voltage (V) of the motor.
200 V Class: 200.0
V, 400 V Class:
400.0 V
(200 V Class: 0.0 -
255.0 V, 400 V
Class: 0.0 - 510.0
V)
1036
T2-06
(0733)
PM Motor Rated
Current
Sets the rated current (A) of the motor.
Determined by o2-
04
(10% to 200% of
the drive rated
current)
1036
T2-07
(0753)
PM Motor Base
Frequency
Sets the base frequency (Hz) of the motor.
87.5 Hz
(0.0 - 590.0 Hz)
1036
T2-08
(0734)
Number of PM
Motor Poles
Sets the number of motor poles.
6
(2 - 48)
1037