11.6 E: Motor Parameters
814 YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
E4-11: Motor 2 Rated Power
No.
(Hex.)
Name Description
Default
(Range)
E4-11
(0327)
Motor 2 Rated Power
Sets the motor 2 rated power in 0.01 kW increments (1 HP = 0.746 kW).
Determined by o2-04
and C6-01
(0.00 - 650.00 kW)
Auto-Tuning automatically sets this parameter to the value input for [Motor Rated Power].
Note:
When the maximum applicable motor output < 300 kW, the drive uses 0.01 kW units. When the maximum applicable motor output >
300 kW, the drive uses 0.1 kW units.
The maximum applicable motor output changes when the value for C6-01 [Normal / Heavy Duty Selection] changes.
E5: PM Motor Settings
E5 parameters are used to set PM motor data.
Set E5-01 to the motor code when using PM motors recommended by Yaskawa. E5 and other related motor
parameters will be automatically set to the optimal values.
Perform Auto-Tuning for all other PM motors. If information from motor nameplates or test reports is available,
the E5 parameters can be manually entered.
Note:
The keypad displays E5-xx only when A1-02 = 5, 6, 7 [Control Method Selection = OLV/PM, AOLV/PM, CLV/PM].
E5-xx parameters are not reset when the drive is initialized using parameter A1-03 [Initialize Parameters].
E5-01: PM Motor Code Selection
No.
(Hex.)
Name Description
Default
(Range)
E5-01
(0329)
PM Motor Code
Selection
Sets the motor code for Yaskawa PM motors. The drive uses the motor code
to set some parameters to their correct settings automatically.
Determined by A1-
02, o2-04, and C6-01
(0000 - FFFF)
Note:
If the drive hunts or shows an alarm after you use a motor code, use the keypad to enter the value shown on the nameplate to E5-xx.
When you use a PM motor other than a Yaskawa SMRA, SSR1, or SST4 series, set E5-01 = FFFF.
Figure 11.76 gives information about the motor code setting digits.
Figure 11.76 PM Motor Code
E5-02: PM Motor Rated Power (kW)
No.
(Hex.)
Name Description
Default
(Range)
E5-02
(032A)
PM Motor Rated
Power (kW)
Sets the PM motor rated power.
Determined by E5-01
(0.10 - 650.00 kW)
These types of Auto-Tuning will automatically set this parameter:
PM Motor Parameter Settings
PM Stationary Auto-Tuning
PM Rotational Auto-Tuning
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV

Table of Contents