EasyManua.ls Logo

YASKAWA GA700 - F: Options; F1: PG Option Setup (Encoder)

YASKAWA GA700
1053 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter List
10
10.9 F: Options
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual 531
10.9 F: Options
F1: PG Option Setup (Encoder)
No.
(Hex.)
Name Description
Default
(Range)
Ref.
F1-01
(0380)
Encoder 1 Pulse
Count (PPR)
Sets the number of output pulses for each motor revolution.
1024 ppr
(1 - 60000 ppr)
821
F1-02
(0381)
Encoder Signal
Loss Detect Sel
Sets the method to stop the motor or let the motor continue
operating when the drive detects a PGo [Encoder (PG) Feedback
Loss].
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
4 : No Alarm Display
1
(0 - 4)
821
F1-03
(0382)
Overspeed
Detection Selection
Sets the method to stop the motor or let the motor continue
operating when the drive detects a oS [Overspeed].
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
4 : No Alarm Display
1
(0 - 3)
821
F1-04
(0383)
Speed Deviation
Detection Select
Sets the method to stop the motor or let the motor continue
operating when the drive detects a dEv [Speed Deviation].
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
3
(0 - 3)
822
F1-05
(0384)
Encoder 1 Rotation
Selection
Sets the output sequence for the A and B pulses from the encoder,
assuming that the motor is operating in the forward direction.
0 : Pulse A leads in FWD Direction
1 : Pulse B leads in FWD Direction
Determined by A1-
02
(0, 1)
822
F1-06
(0385)
Encoder 1 Pulse
Monitor Scaling
Sets the ratio between the pulse input and the pulse output of the
encoder as a 3-digit number. The first digit is the numerator and the
second and third digits set the denominator.
The dividing ratio = (1 + x)/yz when the setting value is a 3-digit
value (xyz).
001
(001 - 032, 102 -
132 (1 - 1/32))
822
F1-08
(0387)
Overspeed
Detection Level
Sets the detection level of oS [Overspeed] as a percentage when the
maximum output frequency is 100%.
115%
(0 - 120%)
823
F1-09
(0388)
Overspeed
Detection Delay
Time
Sets the length of time that the speed feedback must be more than
the F1-08 level to cause an oS [Overspeed].
Determined by A1-
02
(0.0 - 2.0 s)
823
F1-10
(0389)
Speed Deviation
Detection Level
Sets the detection level of dEv [Speed Deviation] as a percentage
when the maximum output frequency is 100%.
10%
(0 - 50%)
823
F1-11
(038A)
Speed Deviation
Detect DelayTime
Sets the length of time that the difference between the frequency
reference and speed feedback must be more than the level in F1-10
to cause a dEv [Speed Deviation].
0.5 s
(0.0 - 10.0 s)
823
F1-12
(038B)
Encoder 1 Gear
Teeth 1
Sets the number of gear teeth on the motor side. This parameter and
F1-13 [Encoder 1 Gear Teeth 2] set the gear ratio between the
motor and encoder.
0
(0 - 1000)
823
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV