Startup Procedure and
Test Run
3
3.2 Component Names and Functions
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual 143
LCD Display
Figure 3.2 LCD Display Indications
Table 3.2 LCD Display Indications and Meanings
Sym
bol
Name Description
A Time display area Shows the current time. Set the time on the default settings screen.
B
Forward run/
Reverse indication
Shows direction of motor rotation.
FWD: Shown when set to Forward run.
REV: Shown when set to Reverse run.
Note:
In DriveWorksEZ operation, FWD or REV flash.
C
Ready The screen will show Rdy when the drive is ready for operation or when the drive is running.
D Mode display area Shows the name of the current mode or screen.
E
Frequency reference
source indicator
Shows the current frequency reference source.
KPD: keypad
AI: analog input terminal (terminals A1 to A3)
COM: MEMOBUS/Modbus communications
OPT: option card
RP: pulse train input terminal (terminal RP)
F Data display area Shows parameter values, monitor values, and details of the results of operations.
G
Function keys 1 to 3
(F1 to F3)
The function names shown in this area will change when the selected screen changes. Push one of the
function keys to on the keypad to do the function.