9.5 Drive Specifications
456 YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
9.5 Drive Specifications
Note:
To get the OLV, CLV, and AOLV specifications, do Rotational Auto-Tuning.
To get the longest product life, install the drive in an environment that meets the necessary specifications.
Table 9.9 Control Characteristics
Item Specifications
Control
Methods
V/f Control (V/f)
Closed Loop V/f Control (CL-V/f)
Open Loop Vector Control (OLV)
Closed Loop Vector Control (CLV)
Advanced Open Loop Vector Control (AOLV)
Open Loop Vector Control for PM (OLV/PM)
Advanced Open Loop Vector Control for PM (AOLV/PM)
Closed Loop Vector Control for PM (CLV/PM)
EZ Open Loop Vector Control (EZOLV)
Frequency
Control Range
AOLV and EZOLV: 0.01 Hz to 120 Hz
CL-V/f, CLV, AOLV/PM, and CLV/PM: 0.01 Hz to 400 Hz
V/f, OLV, and OLV/PM: 0.01 Hz to 590 Hz
Frequency
Accuracy
(Temperature
Fluctuation)
Digital inputs: Within ±0.01% of the maximum output frequency (-10 °C to +40 °C (14 °F to 104 °F))
Analog inputs: Within ±0.1% of the maximum output frequency (25 °C ±10 °C (77 °F ±18 °F))
Frequency
Setting
Resolution
Digital inputs: 0.01 Hz
Analog inputs: 1/2048 of the maximum output frequency (11-bit signed)
Output
Frequency
Resolution
0.001 Hz
Frequency
Setting Signal
Main speed frequency reference: -10 Vdc to +10 Vdc (20 kΩ), 0 Vdc to 10 Vdc (20 kΩ), 4 mA to 20 mA (250 Ω), 0
mA to 20 mA (250 Ω)
Main speed reference: Pulse train input (maximum 32 kHz)
Starting Torque
V/f: 150%/3 Hz
CL-V/f: 150%/3 Hz
OLV: 200%/0.3 Hz
CLV: 200%/0 min
-1
(r/min)
AOLV: 200%/0.3 Hz
OLV/PM: 100%/5% speed
AOLV/PM: 200%/0 min
-1
(r/min)
CLV/PM: 200%/0 min
-1
(r/min)
EZOLV: 100%/1% speed
Note:
Correctly select drive capacity for this starting torque in these control methods:
OLV
CLV
AOLV
AOLV/PM
CLV/PM
Speed Control
Range
V/f: 1:40
CL-V/f: 1:40
OLV: 1:200
CLV: 1:1500
AOLV: 1:200
OLV/PM: 1:20
AOLV/PM: 1:100 (when high frequency injection is enabled)
CLV/PM: 1:1500
EZOLV: 1:100