Specifications
9
9.4 Model Specifications (400 V Class)
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual 449
9.4 Model Specifications (400 V Class)
Table 9.5 Rating (400 V Class)
Model
Input
Voltage
Duty
Rating
4002 4004 4005 4007 4009 4012 4018 4023
Maximum
Applicable Motor
Output (kW)
< 460 V
*1
HD1 0.55 0.75 1.5 2.2 3 3.7 5.5 7.5
ND1 0.75 1.5 2.2 3 3.7 5.5 7.5 11
460 V
*2
HD2 0.55 0.75 1.5 2.2 3 3.7 5.5 7.5
ND2 0.75 1.5 2.2 3 3.7 5.5 7.5 11
Maximum
Applicable Motor
Output (HP)
< 460 V
*1
HD1 3/4 1 2 3 4 5 7 1/2 10
ND1 1 2 3 4 5 7 1/2 10 15
460 V
*2
HD2 3/4 1 2 3 4 5 7 1/2 10
ND2 1 2 3 4 5 7 1/2 10 15
Input
Rated
Input
Current
(A)
*3
< 460 V
HD1
(AC)
1.9 3.5 4.7 6.7 8.9 11.7 15.8 21.2
HD1
(DC)
2.3 4.3 5.8 8.2 11 15 20 26
ND1
(AC)
2.5 4.7 6.7 8.9 11.7 15.8 21.2 30.6
ND1
(DC)
3.1 5.8 8.2 11 15 20 26 38
460 V
HD2
(AC)
1.6 2.1 3.9 5.5 7.4 9.0 13.1 17.5
HD2
(DC)
1.9 2.5 4.8 6.8 9.0 11 16 22
ND2
(AC)
2.1 3.9 5.5 7.4 9.0 13.1 17.5 25.3
ND2
(DC)
2.5 4.8 6.8 9.0 11 16 22 31