9.3 Model Specifications (200 V Class)
448 YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
*5 The rated output capacity is calculated with a rated output voltage of 220 V.
Table 9.4 Rating (200 V Class)
Model 2169 2211 2257 2313 2360 2415
Maximum Applicable Motor
Output (kW)
HD1
*1
37 45 55 75 90 110
ND1
*2
45 55 75 90 110 -
Maximum Applicable Motor
Output (HP)
HD1
*1
50 60 75 100 125 150
ND1
*2
60 75 100 125 150 -
Input
Rated Input
Current
*3
(A)
HD1 (AC) 136 164 200 271 324 394
HD1 (DC) 167 202 245 332 397 483
ND1 (AC) 164 200 271 324 394 -
ND1 (DC) 202 245 332 397 483 -
Outputs
Rated Output
Capacity
(kVA)
HD1
*4
55.3 68.6 81.9 108 132 158
ND1
*5
64.4 80.4 97.9 119 137 -
Rated Output
Current (A)
HD1 145 180 215 283 346 415
ND1 169 211 257 313 360 -
Overload Tolerance
• HD: 150% of the rated output current for 60 seconds
• ND: 110% of the rated output current for 60 seconds
Note:
Derating may be necessary for applications that start and stop frequently.
Carrier Frequency
HD1: 5 kHz without derating the drive capacity.
ND: 2 kHz without derating the drive capacity.
Derate the drive capacity to use values to 10 kHz maximum.
Maximum Output Voltage
Three-phase 200 V to 240 V
Note:
The maximum output voltage is proportional to the input voltage.
Maximum Output Frequency
• Advanced Open Loop Vector Control (AOLV) and EZ Open Loop Vector Control
(EZOLV): 120 Hz
• Closed Loop V/f Control (CL-V/f), Closed Loop Vector Control (CLV), Advanced Open
Loop Vector Control for PM (AOLV/PM), and Closed Loop Vector Control for PM
(CLV/PM): 400 Hz
• V/f Control (V/f), Open Loop Vector Control (OLV), and Open Loop Vector Control for
PM (OLV/PM): 590 Hz
Measures for
Harmonics
DC Reactor Standard internal characteristics
Braking
Device
Braking Transistor External options
EMC Filter
EMC Filter
IEC61800-3, C2/C3
Factory option
• Models 2xxxB: There is a category C3 EMC filter in the drive.
• Models 2xxxC: There is a category C2 EMC filter in the drive.
Power Supply
Rated Voltage/Rated
Frequency
• Three-phase AC power supply 200 V to 240 V at 50/60 Hz
• DC power supply 270 V to 340 V
Permitted Voltage Fluctuation -15% to +10%
Permitted Frequency
Fluctuation
±5%
Input Power
(kVA)
HD1 56.5 68.2 83.1 113 135 164
ND1 68.2 83.1 113 135 164 -
*1 The maximum applicable motor output complies with 208 V motor ratings as specified in NEC Table 430.250. The rated output
current of the drive output amps must be equal to or more than the motor rated current.
*2 The maximum applicable motor output is based on 4-pole, general-purpose 220 V motor ratings. The rated output current of the drive
output amps must be equal to or more than the motor rated current.
*3 Assumes the value at the rated output current. The input current rating changes when the power supply transformer, input reactor,
wiring connections, or power supply impedance change.
*4 The rated output capacity is calculated with a rated output voltage of 208 V.
*5 The rated output capacity is calculated with a rated output voltage of 220 V.