10.7 d: Reference Settings
522 YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
d4: Frequency Reference Hold and Up/Down 2 Function
No.
(Hex.)
Name Description
Default
(Range)
Ref.
d4-01
(0298)
Freq Reference
Hold Selection
Sets the function that saves the frequency reference or the frequency
bias (Up/Down 2) after a Stop command or when de-energizing the
drive.
Set H1-xx [MFDI Function Select] to one of the these values to
operate this parameter:
A [Accel/Decel Ramp Hold]
10/11 [Up/Down Command]
75/76 [Up/Down 2 Command]
0 : Disabled
1 : Enabled
0
(0, 1)
784
d4-03
(02AA)
RUN
Up/Down 2 Bias
Step Frequency
Sets the bias that the Up/Down 2 function adds to or subtracts from
the frequency reference.
0.00 Hz
(0.00 - 99.99 Hz)
786
d4-04
(02AB)
RUN
Up/Down 2 Ramp
Selection
Sets the acceleration and deceleration times for the Up/Down 2
function to apply the bias to the frequency reference.
0 : Use Selected Accel/Decel Time
1 : Use Accel/Decel Time 4
0
(0, 1)
786
d4-05
(02AC)
RUN
Up/Down 2 Bias
Mode Selection
Sets the function that saves the bias value to the drive when you
open or close the two Up/Down 2 Commands [H1-xx = 75, 76]. Set
d4-03 [Up/Down 2 Bias Step Frequency] = 0.00 before you set this
parameter.
0 : Hold when Neither Up/Down Closed
1 : Reset when Neither / Both Closed
0
(0, 1)
787
d4-06
(02AD)
Frequency Ref
Bias (Up/Down 2)
Saves the bias value from the Up/Down 2 Command when the value
set in E1-04 is 100%.
0.0%
(-99.9 - +100.0%)
787
d4-07
(02AE)
RUN
Analog Freq Ref
Fluctuate Limit
If the frequency reference changes for more than the level set to this
parameter, then the bias value will be held. Parameter E1-04
[Maximum Output Frequency] is 100%.
1.0%
(0.1 - 100.0%)
787
d4-08
(02AF)
RUN
Up/Down 2 Bias
Upper Limit
Sets the upper limit of the Up/Down 2 bias as a percentage of E1-04
[Maximum Output Frequency].
100.0%
(0.0 - 100.0%)
788
d4-09
(02B0)
RUN
Up/Down 2 Bias
Lower Limit
Sets the lower limit of the Up/Down 2 bias as a percentage of E1-04
[Maximum Output Frequency].
0.0%
(-99.9 - 0.0%)
788
d4-10
(02B6)
Up/Down Freq
Lower Limit Select
Sets the lower frequency limit for the Up/Down function.
0 : Greater of d2-02 or Analog
1 : d2-02
0
(0, 1)
788
d4-11
(02B7)
Bi-directional
Output Selection
Sets the function that changes the frequency reference to a Bi-
Directional internal frequency reference.
0 : Disabled
1 : Enabled
0
(0, 1)
788
d4-12
(02B8)
Stop Position Gain
Sets the gain to adjust the stopping accuracy. Set this parameter
when b1-03 = 9 [Stopping Method Selection = Stop with Constant
Distance].
1.00
(0.50 - 2.55)
790
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV

Table of Contents

Other manuals for YASKAWA GA700

Related product manuals