Parameter List
10
10.13 o: Keypad-Related Settings
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual 589
No.
(Hex.)
Name Description
Default
(Range)
Ref.
o2-07
(0527)
Keypad RUN
Direction @
Power-up
Sets the direction of motor rotation when the drive is energized and
the keypad is the Run command source.
0 : Forward
1 : Reverse
0
(0, 1)
1020
o2-09
(050D)
Region Code - - -
o2-23
(11F8)
External 24V
Powerloss
Detection
Sets the function to give a warning when the backup external 24 V
power supply turns off when the main circuit power supply is in
operation.
0 : Disabled
1 : Enabled
0
(0, 1)
1020
o2-24
(11FE)
LED Light
Function Selection
Sets the function to show the LED status rings and keypad LED
lamps.
0 : Enable Status Ring & Keypad LED
1 : LED Status Ring Disable
2 : Keypad LED Light Disable
0
(0 - 2)
1021
o2-26
(1563)
Alarm display at
ext. 24V power
When you connect a backup external 24 V power supply, this
parameter sets the function to trigger an alarm when the main circuit
power supply voltage decreases.
Note:
The drive will not run when it is operating from one 24-V
external power supply.
0 : Disabled
1 : Enabled
0
(0, 1)
1021
o2-27
(1565)
bCE Detection
Selection
Sets drive operation if the Bluetooth device is disconnected when
you operate the drive in Bluetooth Mode.
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
4 : No Alarm Display
3
(0 - 4)
1021
◆ o3: Copy Function
No.
(Hex.)
Name Description
Default
(Range)
Ref.
o3-01
(0515)
Copy Keypad
Function Selection
Sets the function that saves and copies drive parameters to a
different drive with the keypad.
0 : Copy Select
1 : Backup (drive → keypad)
2 : Restore (keypad → drive)
3 : Verify (check for mismatch)
4 : Erase (backup data of keypad)
0
(0 - 4)
1021
o3-02
(0516)
Copy Allowed
Selection
Sets the copy function when o3-01 = 1 [Copy Keypad Function
Selection = Backup (drive → keypad)].
0 : Disabled
1 : Enabled
0
(0, 1)
1022