10.22 Parameters Changed by PM Motor Code Selection
648 YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
No. Name Unit Motor Code (setting value of E5-01)
E5-03
PM Motor Rated
Current (FLA)
A 4.1 8.0 10.5 16.5
E5-04 PM Motor Pole Count - 8 8 8 8
E5-05
PM Motor Resistance
(ohms/phase)
Ω 0.538 0.20 0.15 0.097
E5-06
PM d-axis Inductance
(mH/phase)
mH 3.2 1.3 1.1 1.1
E5-07
PM q-axis Inductance
(mH/phase)
mH 3.2 1.3 1.1 1.1
E5-09
PM Back-EMF Vpeak
(mV/(rad/s))
mVs/rad 0 0 0 0
E5-24
PM Motor Induced
Voltage Constant 2
(Ke)
mV/(r/min) 32.4 32.7 36.7 39.7
E1-04
Maximum Output
Frequency
Hz 240 240 240 240
E1-05
Maximum Output
Voltage
V 200.0 200.0 200.0 200.0
E1-06 Base Frequency Hz 240 240 240 240
E1-09
Minimum Output
Frequency
Hz 12 12 12 12
C5-17 Motor Inertia kgm
2
0.0007 0.0014 0.0021 0.0032
L3-24
Motor Accel Time for
Inertia Cal
s 0.137 0.132 0.132 0.122
n5-02
Motor Acceleration
Time
s 0.137 0.132 0.132 0.122
n8-49
d-Axis Cur
forHighEfficiency
Cont
% 0 0 0 0
◆ Yaskawa SSR1 Series IPM Motors (Derated Torque)
Table 10.6 SSR1 Series Motor Code Setting for Specification of 200 V at 1750 min
-1
(r/min)
No. Name Unit Motor Code (setting value of E5-01)
E5-01
PM Motor Code
Selection
- 1202 1203 1205 1206 1208 120A 120B 120D
Voltage Class V 200 200 200 200 200 200 200 200
Capacity kW 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11
Motor Rotation
Speed
min
-1
1750 1750 1750 1750 1750 1750 1750 1750
E5-02
PM Motor Rated
Power (kW)
kW 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11.0
E5-03
PM Motor Rated
Current (FLA)
A 1.77 3.13 5.73 8.44 13.96 20.63 28.13 41.4
E5-04
PM Motor Pole
Count
- 6 6 6 6 6 6 6 6
E5-05
PM Motor
Resistance (ohms/
phase)
Ω 8.233 2.284 1.470 0.827 0.455 0.246 0.198 0.094
E5-06
PM d-axis
Inductance (mH/
phase)
mH 54.84 23.02 17.22 8.61 7.20 4.86 4.15 3.40
E5-07
PM q-axis
Inductance (mH/
phase)
mH 64.10 29.89 20.41 13.50 10.02 7.43 5.91 3.91