Standards Compliance
4
4.2 European Standards
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual 231
■ Main Circuit Wire Gauges and Tightening Torques
WARNING! Electrical Shock Hazard. Only connect peripheral options, for example a DC reactor or braking resistor, to terminals
+1, +2, +3, -, B1, and B2. Failure to obey can cause death or serious injury.
Note:
• Yaskawa recommends wire gauges using drive continuous current ratings of 75 °C (167 °F) 600 V class 2 heat-resistant indoor PVC
wire. Assume these conditions:
–Ambient temperature: 40 °C (104 °F) or lower
–Wiring distance: 100 m (3281 ft.) or shorter
–Normal Duty Rated current value
• Refer to the instruction manual for each device for recommended wire gauges to connect peripheral devices or options to terminals +1,
+2, +3, -, B1, and B2. Contact Yaskawa or your nearest sales representative if the recommended wire gauges for the peripheral devices
or options are out of the range of the applicable gauges for the drive.
Three-Phase 200 V Class
Model Terminals
Recommended
Gauge
mm
2
Applicable
Gauge
(IP20
Applicable
Gauge
*1
)
mm
2
Wire
Stripping
Length
*2
mm
Terminal Screw
Tightening
Torque
N∙m (lb.∙in.)
Size Shape
2004
R/L1, S/L2, T/L3 2.5
2.5 - 10
(2.5 - 10)
10 M4 Slotted (-)
1.5 - 1.7
(13.5 - 15)
U/T1, V/T2, W/T3 2.5
2.5 - 10
(2.5 - 10)
10 M4 Slotted (-)
1.5 - 1.7
(13.5 - 15)
-, +1, +2 2.5
2.5 - 16
(2.5 - 16)
18 M5 Slotted (-)
2.3 - 2.5
(19.8 - 22)
*3
B1, B2 2.5
2.5 - 4
(2.5 - 4)
10 M4 Slotted (-)
1.5 - 1.7
(13.5 - 15)
2.5
*4
2.5 - 10
(-)
- M4
Phillips/slotted
combo
1.2 - 1.5
(10.6 - 13.3)
2006
R/L1, S/L2, T/L3 2.5
2.5 - 10
(2.5 - 10)
10 M4 Slotted (-)
1.5 - 1.7
(13.5 - 15)
U/T1, V/T2, W/T3 2.5
2.5 - 10
(2.5 - 10)
10 M4 Slotted (-)
1.5 - 1.7
(13.5 - 15)
-, +1, +2 2.5
2.5 - 16
(2.5 - 16)
18 M5 Slotted (-)
2.3 - 2.5
(19.8 - 22)
*3
B1, B2 2.5
2.5 - 4
(2.5 - 4)
10 M4 Slotted (-)
1.5 - 1.7
(13.5 - 15)
2.5
*4
2.5 - 10
(-)
- M4
Phillips/slotted
combo
1.2 - 1.5
(10.6 - 13.3)
2010
R/L1, S/L2, T/L3 2.5
2.5 - 10
(2.5 - 10)
10 M4 Slotted (-)
1.5 - 1.7
(13.5 - 15)
U/T1, V/T2, W/T3 2.5
2.5 - 10
(2.5 - 10)
10 M4 Slotted (-)
1.5 - 1.7
(13.5 - 15)
-, +1, +2 2.5
2.5 - 16
(2.5 - 16)
18 M5 Slotted (-)
2.3 - 2.5
(19.8 - 22)
*3
B1, B2 2.5
2.5 - 4
(2.5 - 4)
10 M4 Slotted (-)
1.5 - 1.7
(13.5 - 15)
2.5
*4
2.5 - 10
(-)
- M4
Phillips/slotted
combo
1.2 - 1.5
(10.6 - 13.3)