260 YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
Model Terminals
Recommended
Gauge
AWG, kcmil
Applicable
Gauge
(IP20
Applicable
Gauge
*1
)
AWG, kcmil
Wire
Stripping
Length
*2
mm
Terminal Screw
Tightening
Torque
Nm (lbin.)
Size Shape
2018
R/L1, S/L2, T/L3 10
14 - 6
(14 - 6)
10 M4 Slotted (-)
1.5 - 1.7
(13.5 - 15)
U/T1, V/T2, W/T3 10
14 - 6
(14 - 6)
10 M4 Slotted (-)
1.5 - 1.7
(13.5 - 15)
-, +1, +2 8
14 - 3
(14 - 3)
18 M5 Slotted (-)
2.3 - 2.5
(19.8 - 22)
*3
B1, B2 14
14 - 10
(14 - 10)
10 M4 Slotted (-)
1.5 - 1.7
(13.5 - 15)
10
14 - 8
(-)
- M4
Phillips/slotted
combo
1.2 - 1.5
(10.6 - 13.3)
2021
R/L1, S/L2, T/L3 8
14 - 6
(14 - 6)
10 M4 Slotted (-)
1.5 - 1.7
(13.5 - 15)
U/T1, V/T2, W/T3 10
14 - 6
(14 - 6)
10 M4 Slotted (-)
1.5 - 1.7
(13.5 - 15)
-, +1, +2 8
14 - 3
(14 - 3)
18 M5 Slotted (-)
2.3 - 2.5
(19.8 - 22)
*3
B1, B2 14
14 - 10
(14 - 10)
10 M4 Slotted (-)
1.5 - 1.7
(13.5 - 15)
10
12 - 8
(-)
- M4
Phillips/slotted
combo
1.2 - 1.5
(10.6 - 13.3)
2030
R/L1, S/L2, T/L3 6
14 - 6
(14 - 6)
10 M4 Slotted (-)
1.5 - 1.7
(13.5 - 15)
U/T1, V/T2, W/T3 8
14 - 6
(14 - 6)
10 M4 Slotted (-)
1.5 - 1.7
(13.5 - 15)
-, +1, +2 6
14 - 3
(14 - 3)
18 M5 Slotted (-)
2.3 - 2.5
(19.8 - 22)
*3
B1, B2 12
14 - 10
(14 - 10)
10 M4 Slotted (-)
1.5 - 1.7
(13.5 - 15)
8
10 - 8
(-)
- M5
Phillips/slotted
combo
2.0 - 2.5
(17.7 - 22.1)
2042
R/L1, S/L2, T/L3 6
14 - 6
(14 - 6)
10 M4 Slotted (-)
1.5 - 1.7
(13.5 - 15)
U/T1, V/T2, W/T3 6
14 - 6
(14 - 6)
10 M4 Slotted (-)
1.5 - 1.7
(13.5 - 15)
-, +1, +2 3
14 - 3
(14 - 3)
18 M5 Slotted (-)
2.3 - 2.5
(19.8 - 22)
*3
B1, B2 10
14 - 10
(14 - 10)
10 M4 Slotted (-)
1.5 - 1.7
(13.5 - 15)
8
10 - 8
(-)
- M5
Phillips/slotted
combo
2.0 - 2.5
(17.7 - 22.1)