Troubleshooting
6
6.8 Backup Function Operating Mode Display and Errors
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual 387
Code Name Causes Possible Solutions
rdEr Error Reading Data Backup was executed with o3-02 = 0
[Copy Allowed Selection = Disabled]
set.
Set o3-02 = 1 [Enabled] and backup again.
Code Name Causes Possible Solutions
vAEr Voltage Class, Capacity
Mismatch
The power supply specifications or
drive capacity parameter settings are
different between the keypad and the
drive.
1. Make sure that drive model and the value set in
o2-04 [Drive Model (KVA) Selection] are the
same.
2. Restore the parameters.
Code Name Causes Possible Solutions
vFyE Parameters do not Match The parameters that are backed up in the
keypad and the parameters in the drive
are not the same.
1. Restore or backup the parameter again.
2. Verify the parameters.