Specifications
9
9.9 Peripheral Devices and Options
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual 491
Name Model Purpose
Output Side Noise Filter LF series
To decrease wiring noise.
Note:
Install this option around the drive input power system and as near to the drive
as possible.
Capacitor-Type Noise
Filter
3XYG 1003
To decrease wiring noise. You must only use this option around the drive input
power system. Do not connect this option to the output side.
Momentary Power Loss
Recovery Unit
200V class: P0010
400 V class: P0020
To make sure that the drive has power during the momentary power loss ride-thru
time (2 seconds).
Low-Voltage Manual
Load Switch
“AICUT” LB series
PM motors act as generators when coasting to provide voltage to terminals. Install
this option to prevent electric shock.
Table 9.55 Frequency Settings and Monitor Options
Name Model Purpose
Frequency Meter and
Ammeter
DCF-6A
To use analog signals from the drive to monitor the output frequency and current.
Output Voltmeter SDF-12NH To use analog signals from the drive to monitor the output voltage.
Frequency Setting
Potentiometer (2 kΩ)
RV30YN20S: 2 kΩ
To use an analog input to set the frequency.
Frequency Meter Scale
Correction Resistor
(20 kΩ)
RV30YN20S: 20 kΩ
To adjust the frequency scaling.
Control Dial For
Frequency Setting
Potentiometer
CM-3S
Use this option with the frequency setting potentiometer.
Potential Transformer UPN-B To adjust the meter voltage.
Scale Plate NPJT41561-1 Use this option with the frequency setting potentiometer.
Table 9.56 Keypad Options
Name Model Purpose
LED Keypad JVOP-KPLEA04xxx
A replacement keypad that has an LED display. Use connection cables that are 3
m (9.8 ft) long maximum to connect this keypad for remote operation.
LCD Operator Extension
Cable
WV001 (1 m [3.3 ft]
length)
WV003 (3 m [9.8 ft]
length)
To connect the keypad and drive.
This option is an RJ-45, 8-pin straight-through UTP CAT5e cable.
Installation Support Set A 900-192-933-001 To attach the keypad to the control panel. This option uses screws.
Installation Support Set B 900-192-933-002
To attach the keypad to the control panel. This option uses nut clamps.
Use this option when weld studs are located in the control panel.
Table 9.57 Attachments
Name Model Purpose
External Heatsink Mount
Kit
900-193-209-001
900-193-209-002
900-193-209-003
Use this option to install the heatsink outside of the control panel.
Note:
When you use external heatsink mounting, it may be necessary to decrease the
current.
UL Type 1 Kit
900-192-121-001
900-192-121-002
900-192-121-003
900-192-121-004
900-192-121-005
To change an open chassis type (IP20) drive to an enclosed wall-mounted type
(UL Type 1) drive.
Braking Resistor
Installation Attachment
EZZ020805A
To install a braking resistor to a drive.
External Mounting
Attachment for Braking
Unit Fin
EZZ021711A
To install the heatsink for the braking unit outside of the control panel.