Parameter Details
11
11.5 d: References
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual 797
■ d7-02: Offset Frequency 2
No.
(Hex.)
Name Description
Default
(Range)
d7-02
(02B3)
RUN
Offset Frequency 2
Sets the value to add to or subtract from the frequency reference when H1-
xx = 45 [MFDI Function Select = Add Offset Frequency 2 (d7-02)] as a
percentage of E1-04 [Maximum Output Frequency].
0.0%
(-100.0 - +100.0%)
■ d7-03: Offset Frequency 3
No.
(Hex.)
Name Description
Default
(Range)
d7-03
(02B4)
RUN
Offset Frequency 3
Sets the value to add to or subtract from the frequency reference when H1-
xx = 46 [MFDI Function Select = Add Offset Frequency 3 (d7-03)] as a
percentage of E1-04 [Maximum Output Frequency].
0.0%
(-100.0 - +100.0%)