11.7 F: Options
858 YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
F7-23 to F7-32: Dynamic Out Param 1 to 10 for CommCard
No.
(Hex.)
Name Description
Default
(Range)
F7-23 to F7-
27
(03FB -
03FF)
F7-28 to F7-
32
(0370 - 0374)
Dynamic Out Param
1 to 10 for
CommCard
Sets Output Assembly 116. The drive writes the values from Output
Assembly 116 to the MEMOBUS/Modbus address register that is stored for
each parameter. The drive will not write the values from Output Assembly
116 to the registers when the MEMOBUS/Modbus address is 0.
0
F7-33 to F7-42: Dynamic In Param 1 to 10 for CommCard
No.
(Hex.)
Name Description
Default
(Range)
F7-33 to F7-
42
(0375 - 037E)
Dynamic In Param 1
to 10 for CommCard
Sets Input Assembly 166. The drive sends the values from the MEMOBUS/
Modbus address registers stored for each parameter to Input Assembly 166.
The drive returns the default register value for the option card when the
MEMOBUS/Modbus address is 0 and the value sent to Input Assembly 166
is not defined.
0
F7-60: PZD1 Write (Control Word)
No.
(Hex.)
Name Description
Default
(Range)
F7-60
(0780)
PZD1 Write (Control
Word)
Sets the MEMOBUS/Modbus address for PZD1 (PPO output). PZD1 (PPO
output) functions as the STW when F7-60 = 0, 1, or 2.
0
F7-61: PZD2 Write (Frequency Reference)
No.
(Hex.)
Name Description
Default
(Range)
F7-61
(0781)
PZD2 Write
(Frequency
Reference)
Sets the MEMOBUS/Modbus address for PZD2 (PPO output). PZD2 (PPO
output) functions as the HSW when F7-61 = 0, 1, or 2.
0
F7-62: PZD3 Write
No.
(Hex.)
Name Description
Default
(Range)
F7-62
(0782)
PZD3 Write
Sets the MEMOBUS/Modbus address for PZD3 (PPO output). A value of 0,
1, or 2 will disable the PZD3 (PPO output) write operation to the
MEMOBUS/Modbus register.
0
F7-63: PZD4 Write
No.
(Hex.)
Name Description
Default
(Range)
F7-63
(0783)
PZD4 Write
Sets the MEMOBUS/Modbus address for PZD4 (PPO output). A value of 0,
1, or 2 will disable the PZD4 (PPO output) write operation to the
MEMOBUS/Modbus register.
0
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV

Table of Contents

Other manuals for YASKAWA GA700

Related product manuals